Energy auditing and electricity saving opportunities in BPOM laboratory of manokwari
DOI:
https://doi.org/10.61511/seesdgj.v1i1.2023.22Keywords:
Energy auditing, BPOM, Energy consumption intensity, Energy savingAbstract
Energy auditing is a method of increasing energy efficiency. An energy audit is conducted to provide an overview of energy use, analyze the electrical system, and determine potential cost savings. The laboratory of the national food and drug agency (BPOM) in Manokwari has problems with electricity that often cause interruptions, power outages, and expensive bills. Therefore, this research was conducted to audit the energy used in the laboratory of the BPOM of Manokwari, with a building area of 1,484 m2 and an installed power of 105 kVA. In this laboratory building, a diesel generator with capacity of 5 kVA is installed as a backup energy source and the generator has its own installation line. According to the calculation results before auditing, the energy consumption intensity (IKE) value obtained per month is 10.18 kWh. Energy audit through lighting loads and air conditioning systems. Then the recommendation through energy savings for lights and air conditioners is 274.12 kWh/month and 639.32 kWh/month, respectively. Therefore, total savings are 913.44 kWh/month, or about IDR 1,541,886.72/month.
References
Abdallah, A., Makram, A., & Nayel, M. (2021). Energy audit and evaluation of indoor environment condition inside Assiut International Airport terminal building, Egypt. Ain Shams Engineering Journal, Query date: 2023-06-21.
https://www.sciencedirect.com/science/article/pii/S2090447921001477.
Adewale, A., Adekitan, A., Idoko, O., & ... (2018). Energy audit and optimal power supply for a commercial building in Nigeria. Cogent, Query date: 2023-06-21 13:00:13. https://doi.org/10.1080/23311916.2018.1546658
Agus, R. (2007). Audit Energi dan Analisis Peluang Penghematan Konsumsi Energi pada Sistem Pengkondisian Udara di Hotel Santika Premiere Semarang [Universitas Negeri Semarang]. http://lib.unnes.ac.id/id/eprint/1209
Ahmad Deni, M., & Dzahlusyah. (2019). Audit energi listrik pada gedung analis kesehatan Bandung. JURNAL TEKNIK ENERGI, 9(1), 79–86.
Anagra, F. (2020). Audit Energi dan Analisis Peluang Penghematan Konsumsi Energi Listrik di Unit 1 PLTU Banten 3 Lontar. Jurnal Teknologi Elektro, 11(1), 32-38.
https://publikasi.mercubuana.ac.id/index.php/jte/article/view/8394
Assimakopoulos, M. N., Papadaki, D., Tariello, F., & Vanoli, G. P. (2020). A Holistic Approach for Energy Renovation of the Town Hall Building in a Typical Small City of Southern Italy. Sustainability, 12(18), 7699. https://doi.org/10.3390/su12187699
Atiba, O. E., Efemwenkiekie, U. K., Olatunji, R. O., Ohunakin, O. S., Adelekan, D. S., & Oyeleke, O. A. (2019). Walk-through energy audit of an institutional building. In Journal of Physics: Conference Series (Vol. 1378, No. 3, p. 032051). IOP Publishing
https://doi.org/10.1088/1742-6596/1378/3/032051
Azizul, M. H., Salim, F., & Adnan, S. Z. S. (2023, May). Energy audit exercise at commercial building. A case study and analysis of the 10 years old office building located at Cyberjaya, Selangor Darul Ehsan. In AIP Conference Proceedings (Vol. 2530, No. 1). AIP Publishing.
https://pubs.aip.org/aip/acp/article/2530/1/080006/2891720
Bakoren. (1994). Buku Pedoman tentang Cara-Cara Melaksanakan Konservasi Energi dan Pengawasannya. Direktorat Jenderal Listrik dan Pengembangan Energi Departemen Pertambangan dan Energi. https://pustaka.pu.go.id
Bergero, S., & Chiari, A. (2021). Validation and calibration of dynamic energy models: energy audit of a public building. In Journal of Physics: Conference Series (Vol. 2116, No. 1, p. 012107). IOP Publishing. https://doi.org/10.1088/1742-6596/2116/1/012107
[BPOM] Badan Pengawas Obat dan Makanan. (2016). Sentra Informasi Keracunan Nasional. Jakarta : Badan Pengawas Obat dan Makanan. www.pom.go.id
Čajčíková, J. (2020). Energetický audit polyfunkčního objektu: Energy Audit of Multipurpose Building. Query date: 2023-06-21 13:00:13. core.ac.uk
Chan, M., Arriola, E., Cuevas, R., & Reyes, J. G. (2021). Development of an Energy Audit Working Procedure for an Academic University Office Building in the Philippines. ASEAN Eng. J, 11, 88-95. http://hdl.handle.net/11343/275167
Chisale, S., & Mangani, P. (2021). Energy audit and feasibility of solar PV energy system: Case of a commercial building. Journal of Energy, Query date: 2023-06-21 13:00:13. https://www.hindawi.com/journals/jen/2021/5544664/
Darshan, A., Girdhar, N., Bhojwani, R., Rastogi, K., Angalaeswari, S., Natrayan, L., & Paramasivam, P. (2022). Energy audit of a residential building to reduce energy cost and carbon footprint for sustainable development with renewable energy sources. Advances in Civil Engineering, 2022.
https://www.hindawi.com/journals/ace/2022/4400874/
Deo, A., & Rajput, S. K. (2021). Improving Energy Efficiency and Reducing CO 2 Emission of Institutional Building: An Energy Audit Case Study. In Latest Trends in Renewable Energy Technologies: Select Proceedings of NCRESE 2020 (pp. 137-146). Springer Singapore. https://doi.org/10.1007/978-981-16-1186-5_11
Egwunatum, S. I., & Akpokodje, O. I. (2019). Economic aspects of building Energy audit. In Zero and Net Zero Energy. IntechOpen. DOI: 10.5772/intechopen.85490
https://www.intechopen.com/chapters/67283
Energi (2007). Energy Independence and Security Act of 2007. https://www.energy.gov/ceser/energy-independence-and-security-act-2007.
Ghadi, Y. Y., & Baniyounes, A. M. (2018). Energy audit and analysis of an institutional building under subtropical climate. International Journal of Electrical and Computer Engineering (IJECE), 8(2), 845-852. DOI: 10.11591/ijece.v8i2.pp845-852
Hassan, M. T., Abdelgeliel, M., & Hamad, M. S. (2022). ENERGY audit and management on residential and commercial building: A case study. In 2022 11th International Conference on Renewable Energy Research and Application (ICRERA) (pp. 424-429). IEEE. https://ieeexplore.ieee.org/abstract/document/9922771/
Karmiathi, N. M., & Putra, I. K. A. (2022). Technical analysis of power factor improvement using ETAP 12.6 at Regent Resort & Holiday Inn Canggu. Matrix: Jurnal Manajemen Teknologi dan Informatika, 12(1), 38-50
https://ojs2.pnb.ac.id/index.php/MATRIX/article/view/402
Kumar, G., Kim, S. H., Lay, C. H., & Ponnusamy, V. K. (2020). Recent developments on alternative fuels, energy and environment for sustainability. Bioresource technology, 317, 124010. https://www.ijrter.com/papers/volume-6/issue-6
MAUL, M. I. (2018). AUDIT ENERGI DAN PERANCANGAN BUILDING ENERGY MANAGEMENT SYSTEM UNTUK RUANG E5 DAN E6 DEPARTEMEN TEKNIK ELEKTRO DAN TEKNOLOGI INFORMASI UNIVERSITAS GADJAH MADA (Doctoral dissertation, Universitas Gadjah Mada).http://etd.repository.ugm.ac.id/penelitian/detail/164693
Merabtine, A., Maalouf, C., Hawila, A. A. W., Martaj, N., & Polidori, G. (2018). Building energy audit, thermal comfort, and IAQ assessment of a school building: A case study. Building and Environment, 145, 62-76.
https://www.sciencedirect.com/science/article/pii/S0360132318305638
Muhammad, J. Y. U., Adamu, A. A., Alhaji, A. M. I., & Ali, Y. Y. (2018). Energy Audit and Efficiency of a Complex Building: A Comprehensive Review. Engineering Science, 3(4), 36-41.https://www.researchgate.net/profile/Jamilu-Yau-Muhammad/
Nkwaze, D. C., Aruwajoye, J. B., Aderoju, P. A., Shitta, M. B., Ogedengbe, E. O., & Odumuyiwa, V. T. (2019). Development of a Renewable Energy Sizing Calculator for Building Energy Audit and Appliance'Performance Assessment. In AIAA Propulsion and Energy 2019 Forum (p. 4407). https://doi.org/10.2514/6.2019-4407
Norhisham, M., Razali, M., Amin, M.(2022). Review on Preliminary Energy Audit for 27 Years Old Building at Kemaman Terengganu, Malaysia. Journal of Complex. http://fazpublishing.com/jcf/index.php/jcf/article/view/43
Norouzi, N., Nasiri, Z., & Kalantari, G. (2020). An Introduction to Green Building Energy Audit, LAP Lambert. ISBN, Query date: 2023-06-21 13:00:13.
Regulation No. 13, 2012. https://leap.unep.org/countries/id/case-studies/indonesia
Santika, M. E., & Ruslan, W.( 2022) CASE STUDY OF ENERGY AUDIT IN CV MANNA ANUGERAH SEJAHTERA BUILDING (INDONESIA). (IJAER) 2022, Vol. No. 23, Issue No. I, January. https://ijaer.com/admin/upload/01%20Maria%20Enggar%2001186.pdf
Sönmez, T., Neşe, S. V., Uslu, B. Ç., Akpolat, A. N., & Dursun, E. (2022). Energy saving potential and energy audit of a faculty building at Marmara University in Türkiye. Turkish Journal of Electromechanics and Energy, 7(2). https://openaccess.marmara.edu.tr
Supriyo, S., Margana, M., Purwati, W., Suwarti, S., & ... (2022). Energy Audit of Flouresen Lights at School Building C III Floor Politeknik Negeri Semarang. Eksergi, https://jurnal.polines.ac.id/index.php/eksergi/article/view/3890
Surya Ganesputra, I. M., Janardana, l G. N., & Budiastra, I. N. (2022). STUDI MANAJEMEN ENERGI LISTRIK DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI LISTRIK PADA GEDUNG PENGADILAN NEGERI DENPASAR. Jurnal SPEKTRUM; Vol 9 No 2 (2022): Jurnal SPEKTRUMDO- 10.24843/SPEKTRUM.2022. V09.I02.P14. https://ojs.unud.ac.id/index.php/spektrum/article/view/90008
Thakur, N., Prasath Kumar, V. R., & Balasubramanian, M. (2018). Comparative Energy Audit of Building Models Using BIM for the Sustainable Development. J. Adv. Res. Dyn. Control Syst, 10, 986-992.
Yazid, N. C., & Denny, I. (2023). Audit Energi Listrik Gedung Baru Universitas Muhammadiyah Gresik. Jurnal Power Elektronik, Vol.12, No.1, 2023, 12(1), 8–11. http://dx.doi.org/10.30591/polektro.v12i1.4699
Downloads
Published
How to Cite
Issue
Section
Citation Check
License
Copyright (c) 2023 Social, Ecology, Economy for Sustainable Development Goals Journal

This work is licensed under a Creative Commons Attribution 4.0 International License.